MYSTYLE SOFTWARE
Installation Instructions
30
EAS
TABLE OF CONTENTS INTRODUCTION HARDWARE INSTALLATIONS MYSTYLE SOFTWARE
TABLE OF CONTENTS INTRODUCTION HARDWARE INSTALLATIONS MYSTYLE SOFTWARE
RESISTANCE
(Ohms)
TEMP C
96.40 -55
13.03 -25
3.27 0
1.00 25
0.30 55
0.06 105
Figure 49
In this case, you would choose
the Resistance (ohms) Custom
option.
Another example would be that
of a Pressure Sensor. In Figure
50, the chart shows a Pressure
value that corresponds to a Volt-
age Value.
VOLTAGE PRESSURE
(KPa)
4.9 0
4.4 10
3.8 20
3.3 30
2.7 40
2.2 50
1.7 60
1.1 70
0.6 80
0.3 90
0.3 100
Figure 50
In this case, you would choose
the Voltage (V) Custom option.
If your data sheet does not come
with a chart, but rather gives
you an equation to use, you
will need to calculate the input
values based on the equation
variables.
2) Choose a Pull-up Value.
The values available are 10K
ohm, 1K ohm, or None. To help
determine which pull-up value
to use, refer to the following
rule of thumb:
-3 wire sensors: None
-2 or 1 wire sensors: 1K or 10K
If for example your sensor is a
single wire Temperature sensor,
and is rated as 1K @ 25C, you
would want to use a 1K pull-up.
You want to match your pull-
up value as close to the sensor
rating as possible.
3) Set the alert value according
to your speci c sensor.
Depending on the sensor, the
alert value will be either a maxi-
mum or a minimum value.
For example, if you have a pres-
sure sensor, and you want the
CTS to alert you when the sen-
sor reads greater than or equal
to 90 psi, set up the values as
shown: